SMTC
SS/PBCH Block Measurement Timing Configuration: the window that tells a device when to look for SSBs on a frequency it must measure, set by a period, an offset and a duration.
SSBs aren't sent continuously, so a UE measuring another frequency needs to know when to look. The SMTC gives a periodicity of 5, 10, 20, 40, 80 or 160 ms, an offset in subframes and a window of 1 to 5 ms, and outside that window the UE can assume there's nothing to find. It's configured per frequency in the measurement object (and in SIB2 and SIB4 for idle-mode measurements), and a second SMTC can cover cells whose SSBs run on a different period.
SMTC errors are quiet. If the window doesn't line up with when the neighbor actually sends its SSBs, for example between networks that aren't time-synchronized, or after someone changes the SSB period on one side, the UE simply never reports the neighbor. You see missing B1 reports in EN-DC, inter-frequency handovers that never trigger, and a neighbor that's strong on the scanner but absent from the UE's measurements.
Related terms
Want to truly understand SMTC? Learn it in context.
A free account opens the first module of all 14 certification courses — its video lessons and a hands-on lab — no card. Lifetime Prime Membership opens the rest of every course, the certification exams and a verifiable certificate, for one payment.
- The first module of every course
- Video lessons and a lab
- No card needed
- TELCOMA since 2009
Get one 5G/LTE engineering deep-dive a fortnight
One thing explained properly every other Tuesday — a real failure, and the lab or trace where you work it yourself. No spam, no marketing, just engineering. Unsubscribe in one click.